Supporting structure
Timber mullions and transoms. The variants documented by the Passive House Institute use an aluminium pressure plate and cap.
Aluminium façades / TimberWall 50
A hybrid mullion-and-transom façade with exposed timber inside and aluminium components outside.
Construction principle
Buildings where exposed timber is part of the interior architecture.
Timber mullions and transoms. The variants documented by the Passive House Institute use an aluminium pressure plate and cap.
Aluminium pressure plate and cap in the certified 52 mm variant.
The Passive House Institute documents two reference interior widths, 52 mm and 62 mm.
Technical data
The certified 52 mm variant uses 48 mm triple glazing (6/16/4/16/6).
| Criterion | Value or checks required |
|---|---|
| Reference interior mullion | 52 mm |
| Reference triple glazing | 48 mm |
| Reference mullion U-value | 0.81 W/(m²·K) |
| Curtain wall thermal transmittance Ucw | Determine this for the project's grid and infill panels. |
| Air, water and wind | Check the variant's test report and the spans in the project. |
| Acoustics | Assess from the glazing, panels and joints. |
The values above apply to the configuration described. Manufacturer documentation · Reference data sheet
Materials and colours
Compare colours, surface finishes and the contrast between inside and outside. Availability varies by system.
On-screen colours are indicative. Confirm the colour, matt or satin texture and handles using samples.
System references
See the system page and its variants for sections, glazing options and available illustrations.
Your project
Specify the opening type, any dimensions you know and any constraints at the site.